user_interface-ntb
This is an old revision of the document!
User Interface
Following buttons are available:
- Emergency: red
- Start: green
- Stop: blue
Following actions are possible:
Action | Button |
---|---|
Start 'auto moving' when the robot is ready, i.e. after initializing | green |
Trigger an emergency | red |
Initialize robot after an emergency | green |
Stop 'auto moving' or 'mouse' sequence | blue |
Park the robot, stop application and shut down | blue button three times or for more than three seconds |
TODO
- Stop button: Press while in the
CalibrateBlockSequence
to continue to the next step.
- Start button together with stop button: If both buttons are pressed together in safety level
slSystemReady
the robot will start its calibration sequence.
Each of the three buttons contain a LED giving the buttons its color.
- The red emergency button lights up as soon as the robot goes into emergency state. It will switch off upon leaving this state.
- The green and blue LED indicates that the associated button can be pressed, see above.
user_interface-ntb.1565360869.txt.gz · Last modified: 2019/08/09 16:27 by visentin