==== Motor Model==== | ==== Motor Model==== | ||
- | As our board cannot only control voltages fed to each motor, we must use a motor model to calculate these voltages. The block 'Motor Model' gets the actual speed and the calculated torque as input, and outputs the desired voltage for each motor. | + | As our board cannot only control voltages fed to each motor, we must use a motor model to calculate these voltages. The block 'Motor Model' gets the actual speed and the calculated torque as input, and outputs the desired voltage for each motor. |
+ | < | ||
+ | U = kM * w + I * RA + dI/dt * L | ||
+ | </ | ||
+ | with I = M / kM and dI/dt * L beeing very small with our motors and accounting for the gear i we get | ||
+ | < | ||
+ | U = kM * w * i + M * RA / (kM * i) | ||
+ | </ | ||
==== Outputs ==== | ==== Outputs ==== | ||
The drive signals to the motor are of type '' | The drive signals to the motor are of type '' |